- Product description
-
Product description
Pluggable data line protection, type 1+2/D1+C2 for use in measurement and control technology
• Protection device for multi-wire systems
• Direct shield earthing
• Frequency range up to 100 MHz
• Earthing via DIN rail or connection cable
• Installation width from 12.5 mm
• High system availability – no signal interruption without protection module
Application: Universal lightning and surge protection for MCR data transmission devices.
- Technical data
-
Technical data
Capacity (wire-earth) ≤30 pF Capacity (wire-wire) ≤30 pF Connection cross-section, flexible, max. 1,5 mm² Connection cross-section, flexible, min. 0,14 mm² Connection cross-section, multi-wire, max. 2,5 mm² Connection cross-section, multi-wire, min. 0,14 mm² Connection cross-section, rigid, max. 2,5 mm² Connection cross-section, rigid, min. 0,14 mm² Cut-off frequency 100 MHz Dimension 12V Earthing via: Connection cable / DIN rail Height 95 mm Impulse durability wire-earth 10 kV / 5 kA Impulse durability wire-wire 10 kV / 5 kA Insertion loss ≤3 dB Kategorie Type 1+2 / D1+C2 Length 76 mm Lengthwise resistance 1.2 ± 5% Lightning impulse current 2,5 kA Lightning protection zone LPZ 0→2 Maximum continuous voltage AC 12 V Maximum continuous voltage DC 16 V Mounting of input / output Screw terminals Nominal discharge current (8/20 µs) 10 kA Nominal load current AC 0,425 A Nominal load current DC 0,6 A Number of poles 4 Permitted temperature range, max. 80 °C Permitted temperature range, min. -40 °C Plug-in system Terminal Protection level wire-earth 850 V Protection level wire-wire 130 V Protection rating IP20 Screening Direct Series resistance per wire 1,2 Ω ± 5% Shielding connection available yes Signalling on device None SPD to EN 61643-11 Type 1+2 SPD to IEC 61643-1 Class I+II SPD to IEC 61643-21 Class I+II / D1+C2 Testing standard IEC 61643-21 Total discharge current (10/350) 2,5 kA Total discharge current (8/20) 20 kA Total impulse durability into C2 (8/20) 20 kA Version for 2x2-pole Width 13 mm - All types
-
All types
- Downloads
-
Data sheet PDP-2x2-12-D / 5080319 , 0.27MB , pdfCatalogue Überspannungsschutz , 28.42MB , pdfDeclaration of conformity PDP-2x2-12-D / 5080319 , 0.11MB , pdfREACH Declaration of conformity PDP-2x2-12-D / 5080319 , 0.12MB , pdfRoHS Declaration of conformity PDP-2x2-12-D / 5080319 , 0.12MB , pdfSelection aid Selection aid, surge protection , 2.00MB , pdfMounting instructions Steckbarer Datenleitungsschutz PDP 12V , 2.98MB , pdf
United Arab Emirates - English